Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
World J Urol ; 42(1): 280, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693433

RESUMO

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Assuntos
Falso Aneurisma , Litotripsia a Laser , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Ureteroscopia/efeitos adversos , Adulto
2.
Fr J Urol ; : 102644, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759842

RESUMO

OBJECTIVES: To characterize and compare in vitro the surfaces of ureteral stents(STENTS) before utilization. METHODS: Our in vitro experiment included six unused STENTS models: three double-pigtail with side orifices(ImaJin and Stenostent(Coloplast©,France), TriaSoft(BostonScientific©,USA)), two double-pigtail without side orifice(Vortek-TumorStent (Coloplast©,France), Urosoft-TumorStent(Bard-Angiomed©,Germany)) and one single-pigtail(J-Fil(Rocamed©,Monaco)). STENTS were made of polyurethane except for ImaJin(silicone). For all STENTS, four parts of the stent were specifically analyzed under high-resolution scanning electron microscopy(HR-SEM,FEI-XL40(Philips©,France): surface core, lateral orifice, ureteral loop, and black marking surface. Each experiment was repeated with three different samples from three different stents. STENTS analysis included multiple imperfection searches, defined as irregularities>10µm. RESULTS: All STENTS presented imperfections with no discernible differences. Imperfections were mainly located on the stent loop and on the lateral orifice. For STENTS without side orifice (J-Fil, Urosoft) imperfections were also reported, on the beveled cut as well as the distal loop orifice. Marking surfaces examinations found defects in the Urosoft and imperfections in the ImaJin and Stenostent. The Triasoft presented a better smoothness on marking surfaces compared to other STENTS. Additional matter was reported on the loop distal orifice for J-Fil and ImaJin but all STENTS presented irregular cross-sectional aeras. CONCLUSION: All ureteral stents are not perfectly smooth even before utilization. Imperfections were noticed regardless to stent composition or shape, and could play a role in the incrustation phenomenon, is association with inner irregularities, infection, and urine composition. Both manufacturing and material could have an impact on the stent external surface's smoothness. [[[fr]]]Resumen Objectifs: Caractériser et comparer in vitro les surfaces des endoprothèses urétérales (EU) avant leur utilisation. Méthodes: Notre étude in vitro comprenait six modèles d'EU non utilisées : deux double J avec orifices latéraux (ImaJin et Stenostent(Coloplast©,France), TriaSoft(BostonScientific©,USA)), deux double J sans orifice latéral (Vortek-TumorStent(Coloplast©,France), Urosoft-TumorStent(Bard-Angiomed©,Allemagne)) et une simple J (J-Fil(Rocamed©,Monaco)). Les EU étaient en polyuréthane, à l'exception de ImaJin Coloplast© en silicone. Pour toutes les EU, quatre parties de l'endoprothèse ont été spécifiquement analysées au microscope électronique à balayage à haute résolution (HR-SEM,FEI-XL40(Philips©,France)) : le corps de la sonde, l'orifice latéral, la boucle et la surface de marquage noire. Chaque expérience a été répétée à trois fois avec trois stents différents. L'analyse des EU comprenait la recherche d'imperfections définies comme des irrégularités>10µm. Résultats: Toutes les EU présentaient des imperfections sans différence notable. Les imperfections étaient principalement localisées sur la boucle de l'endoprothèse et sur l'orifice latéral. Pour les EU sans orifice latéral (J-Fil, Urosoft), des imperfections ont également été notées, sur les zones de section ainsi que sur l'orifice distal au niveau de la boucle. L'observation des surfaces de marquage ont révélé des imperfections sur l'Urosoft et de multiples imperfections sur l'Imajin et Stenostent. Triasoft présentait une surface plus lisse au niveau des zones de marquage en comparaison aux autres EU. Du matériel additionnel a été retrouvé sur les extrémités de la J-Fil et de ImaJin, mais toutes les EU présentaient des zones de section irrégulières au niveau des extrémités. CONCLUSION: Toutes les endoprothèses urétérales ne sont pas parfaitement lisses avant leur utilisation. Des imperfections ont été observées indépendamment de la composition ou de la forme de l'endoprothèse, et pourraient jouer un rôle dans le phénomène d'incrustation, en association avec les irrégularités internes, l'infection et la composition de l'urine. La fabrication et le type de matériau pourraient avoir un impact sur l'aspect lisse de la surface externe de l'endoprothèse.

3.
Eur Urol Focus ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38789313

RESUMO

BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the stone-free status (SFS) rate and complications after flexible ureteroscopy (fURS) for treatment of renal stones using a flexible and navigable suction (FANS) ureteral access sheath. METHODS: Data for adults undergoing fURS in 25 centers worldwide were prospectively collected (August 2023 to January 2024). Exclusion criteria were abnormal renal anatomy and ureteral stones. All patients had computed tomography scans before and within 30 d after fURS with a FANS ureteral access sheath. SFS was defined as follows: grade A, zero fragments; grade B, a single fragment ≤2 mm; grade C, a single fragment 2.1-4 mm; and grade D, single/multiple fragments >4 mm. Data for continuous variables are presented as the median and interquartile range (IQR). Multivariable logistic regression was performed to evaluate predictors of grade A SFS. KEY FINDINGS AND LIMITATIONS: The study enrolled 394 patients (59.1% male) with a median age of 49 yr (IQR 36-61). The median stone volume was 1260 mm3 (IQR 706-1800). Thulium fiber laser (TFL) was used in 45.9% of cases and holmium laser in the rest. The median lasing time was 18 min (IQR 11-28) and the median operative time was 49 min (IQR 37-70). One patient required a blood transfusion and 3.3% of patients had low-grade fever. No patient developed sepsis. Low-grade ureteral injury occurred in eight patients (2%). The grade A SFS rate was 57.4% and the grade A + B SFS rate was 97.2%, while 2.8% of patients had grade C or D SFS. Eleven patients underwent repeat fURS. Multivariable analysis revealed that a stone volume of 1501-3000 mm3 (odds ratio 0.50) and of >3000 mm3 (odds ratio 0.29) were significantly associated with lower probability of grade A SFS, while TFL use was associated with higher SFS probability (odds ratio 1.83). Limitations include the lack of a comparative group. CONCLUSIONS AND CLINICAL IMPLICATIONS: fURS using a FANS ureteral access sheath resulted in a high SFS rate with negligible serious adverse event and reintervention rates. PATIENT SUMMARY: We looked at 30-day results for patients undergoing telescopic laser treatment for kidney stones using a special type of vacuum-assisted sheath to remove stone fragments. We found a high stone-free rate with minimal complications.

4.
World J Urol ; 42(1): 355, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38796790

RESUMO

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Assuntos
Desenho de Equipamento , Iluminação , Ureteroscópios , Ureteroscopia , Luz , Humanos , Solução Salina , Cor
5.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613608

RESUMO

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Hólmio , Túlio , Ureteroscopia , Estudos Prospectivos , Cálculos Renais/cirurgia , Lasers
6.
J Endourol ; 38(5): 488-498, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38429915

RESUMO

Urothelial carcinoma (UC) affecting the urinary tract is recognized as one of the prevalent types of cancer, ranking fifth in terms of incidence. However, it is important to note that upper tract urothelial carcinoma (UTUC), in comparison to bladder cancer, is relatively uncommon and represents a minority of UC cases, accounting for ∼5% to 10%. It is worth emphasizing that as much as 60% of UTUC cases are invasive at the time of diagnosis, in contrast to 25% of bladder cancer cases. These statistics highlight the urgent need for well-designed, multidisciplinary strategies to guide optimal management for this vulnerable patient population, aiming to control treatment variability and minimize the risks associated with undertreatment and overtreatment. Methods: In this study, we present a comparative analysis of the contemporary guidelines on UTUC management from the European Association of Urology (EAU) and the American Urological Association/Society of Urologic Oncology (AUA/SUO) released in 2023. Our objective is to contrast the different guidelines and examine the evidence on which their recommendations are based. Results: By thoroughly reviewing the guidelines from both organizations, we observed substantial agreement on the management of UTUC. However, we also identified noticeable differences among these guidelines, leading to a wide range of recommendations. These disparities might stem from variations in clinical practices, regional preferences, and the availability of resources. It is crucial to acknowledge that both the EAU and AUA/SUO base their guidelines on the latest scientific evidence and expert consensus within their respective regions. Conclusions: These findings underscore the importance of ongoing collaboration, knowledge exchange, and harmonization of guidelines to improve the standard of care for UTUC globally. Future research should focus on identifying areas of consensus and bridging the gaps between different international guidelines to enhance the management outcomes for this challenging disease.


Assuntos
Guias de Prática Clínica como Assunto , Humanos , Europa (Continente) , Estados Unidos , Carcinoma de Células de Transição/terapia , Carcinoma de Células de Transição/diagnóstico , Carcinoma de Células de Transição/patologia , Neoplasias Urológicas/terapia
7.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
8.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280001

RESUMO

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Nefrolitíase , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Túlio , Cistina , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio
9.
World J Urol ; 41(12): 3765-3771, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37833547

RESUMO

BACKGROUND AND OBJECTIVE: We aimed to evaluate the concordance between the pre-settings ranges of thulium fibre laser (TFL) (Coloplast TFL Drive, Denmark) with easy-to-use graphical user interface and the laser settings used by a high-volume endo-urologist during surgical procedures. MATERIALS AND METHODS: In October 2022, we prospectively collected data of 67 patients who underwent TFL Drive (Coloplast, Denmark) for the management of urinary stones. Urothelial tumour (upper tract urinary cancer (UTUC) and bladder) 200 and 150 µm laser fibres were used for procedures. Stones characteristics (size and density) tumours and stenosis localizations, laser-on time (LOT), and laser settings were recorded. We also assessed the ablation speed (mm3/s), laser power (W), and Joules/mm3 values for each lithotripsy. RESULTS: A total 67 patients took part in the study. Median age was 52 (15-81) years. 55 (82%), 8 (12%), and 4 (6%) patients presented urinary stones, urothelial tumour, and stenosis, respectively. Median stone volume was 438 (36-6027) mm3 and median density was 988 (376-2000) HU. Median pulse energy was 0.6 (0.3-1.2), 0.8 (0.5-1) and 1 J for urinary stones, urothelial tumour and stenosis respectably. Endoscopically stone-free rate was 89%. Graphical user interface and surgeon accordance with the safety range were observed in 93.2%, 100% and 100% for urinary stones, UTUC and stenosis, respectively. CONCLUSION: During endoscopic procedures for urinary stones treatment, it is frequently needed to change laser parameters. These new TFL and GUI technology parameters remained in the pre-set security range in 94.1% of procedures.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Neoplasias , Cálculos Urinários , Humanos , Pessoa de Meia-Idade , Túlio , Litotripsia a Laser/métodos , Constrição Patológica , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico
10.
J Clin Med ; 12(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37568309

RESUMO

INTRODUCTION: Thulium lasers (TLs), namely the Thulium fiber laser (TFL) and the Thulium:YAG (Tm:YAG), are being increasingly adopted for the conservative treatment of upper urinary tract urothelial carcinoma (UTUC). However, to date, the real clinical impact of TLs on UTUC management remains not well-characterized. We performed a review of the literature to summarize the current evidence on TLs for UTUC treatment. MATERIALS AND METHODS: We performed a systematic review in January 2023 using the Embase and Medline online databases, according to the PRISMA recommendations and using the PICO criteria. Outcomes of interest were: (i) to assess the safety and feasibility of TLs in the treatment of UTUC, and (ii) to evaluate the oncological outcomes in terms of tumor recurrence and conservative treatment failure. Moreover, we described TL characteristics and its interaction with soft tissue. RESULTS: a total of 458 articles were screened, and six full texts including 273 patients were identified. All the included studies were retrospective series. Mean patient age ranged from 66 to 73 years. The indication of a conservative treatment was elective and imperative in 21.7-85% and 15-76% of cases, respectively. Laser power settings varied from 5 to 50 W. No intraoperative complications were reported, and all the procedures were successfully performed. The tumor recurrence rate was 17.7-44%, and the indication to radical nephroureterectomy was 3.7-44% during a follow-up of 6-50 months. Most of the postoperative complications were mild and transient, and ureteral strictures were reported in two studies. Major limitations were the retrospective nature of the studies, the small sample sizes, and the short follow-up. CONCLUSIONS: TL is an effective and safe technology for endoscopic UTUC treatment. However, current available literature lacks prospective and multicentric studies with large population sizes and long-term follow-up.

11.
World J Urol ; 41(8): 2119-2125, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37414942

RESUMO

INTRODUCTION: Holmium:yttrium-aluminium-garnet (Ho:YAG) and thulium fiber (TFL) lasers are currently the two laser sources recommended for endocorporeal laser lithotripsy (ELL). Recently, the pulsed-thulium:YAG (Tm:YAG) laser was also proposed for ELL, as an answer to both Ho:YAG and TFL limitations. We aimed to evaluate the efficiency, safety, and laser settings of Tm:YAG laser in ELL during retrograde intrarenal surgery (RIRS). METHODS: A prospective study of the first 25 patients with ureteral and renal stones who underwent RIRS using the Thulio (pulsed-Tm:YAG, Dornier©, Germany) was performed in a single center. 272 µm laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm3/s), Joules/mm3 and laser power (W) values for each procedure. Postoperative results, such as stone-free rate (SFR) and zero fragments rate (ZFR) were also recorded. RESULTS: A total of 25 patients were analyzed (Table 1). The median (IQR) age was 55 (44-72) years old. Median (IQR) stone volume was 2849 (916-9153)mm3. Median (IQR) stone density was 1000 (600-1174)HU. Median (IQR) pulse energy, pulse rate and total power were 0.6 (0.6-0,8)J, 15(15-20)Hz and 12(9-16)W, respectively. All procedures used "Captive Fragmenting" pulse modulation (Table 2). The median (IQR) J/mm3 was 14,8 (6-21). The median (IQR) ablation rate was 0,75 (0,46-2)mm3/s. One postoperative complications occurred (streinstrasse). SFR and ZFR were 95% and 55%, respectively. CONCLUSION: The pulsed-Tm:YAG laser is a safe and effective laser source for lithotripsy during RIRS, using low pulse energy and low pulse frequency.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Pessoa de Meia-Idade , Idoso , Lasers de Estado Sólido/uso terapêutico , Túlio/uso terapêutico , Estudos Prospectivos , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia , Hólmio
12.
J Clin Med ; 12(8)2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37109152

RESUMO

OBJECTIVE: The aim of this review is to summarize the existing suction systems in flexible ureteroscopy (fURS) and to evaluate their effectiveness and safety. METHODS: A narrative review was performed using the Pubmed and Web of Science Core Collection (WoSCC) databases. Additionally, we conducted a search on the Twitter platform. Studies including suctions systems in fURS were included. Editorials, letters and studies reporting intervention with semirigid ureteroscopy, PCNL and mPCNL were excluded. RESULTS: A total of 12 studies were included in this review. These studies comprised one in vitro study, one ex vivo study, one experimental study and eight cohort studies. The Pubmed and WoSCC searches identified three suction techniques (Irrigation/Suctioning system with control of pressure, suction ureteral access sheath (sUAS) and direct in scope suction (DISS)), and the Twitter search identified four of them. The overall results showed that suction is an effective and safe technique that improves stone-free rates, reduces operative time and limits complication rates after fURS. CONCLUSIONS: The use of suctioning during common endourological procedures has been shown to improve safety and efficacy in several indications. However, randomized controlled trials are needed to confirm this.

13.
Curr Opin Urol ; 33(4): 318-323, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37014757

RESUMO

PURPOSE OF REVIEW: Nowadays, due to the increase of imaging diagnosis, we identify easily renal anomalies, and we can choose between a wide range of armamentarium to treat symptomatic stones in those challenging cases. However, there is a lack of evidence and consensus on its use. The aim of this narrative review is to collect all the available data about safety and efficacity of retrograde intrarenal surgery (RIRS) in the treatment of kidney stones associated to a renal anomaly. RECENT FINDINGS: Renal anomalies are uncommon findings and even more if it has to be associated with renal stones. After a literature review of the past 2 years, there are a small number of studies that compare the outcomes in patients who have been treated with minimally invasive modalities and they are mainly focus on RIRS. SUMMARY: It is of extreme importance to know the advances on the stone treatment in anomalous kidneys. With the development of new laser technologies, RIRS is becoming a more interesting technique with high success rate and safety. Further studies are needed to make an accurate statement about the adequate surgical technique for each renal anomaly and also, clinical trials using new laser technologies.


Assuntos
Divertículo , Rim Fundido , Cálculos Renais , Rim em Esponja Medular , Nefrostomia Percutânea , Humanos , Rim Fundido/complicações , Rim Fundido/diagnóstico por imagem , Rim Fundido/cirurgia , Rim em Esponja Medular/complicações , Rim em Esponja Medular/diagnóstico por imagem , Rim em Esponja Medular/cirurgia , Resultado do Tratamento , Cálculos Renais/complicações , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Rim/diagnóstico por imagem , Rim/cirurgia , Estudos Retrospectivos , Nefrostomia Percutânea/métodos
16.
J Clin Med ; 11(23)2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36498799

RESUMO

Urinary tract infection (UTI) is considered to be a major problem in pregnant women. It is also one of the most prevalent infections during pregnancy, being diagnosed in as many as 50-60% of all gestations. Therefore, UTI treatment during pregnancy is extremely important and management guidelines have been published worldwide to assist physicians in selecting the right antibiotic for each patient, taking into account the maternal and fetal safety profile. A review of the literature was carried out and all international guidelines giving recommendations about antibiotic treatments for pregnancy-related UTI were selected. The search came back with 13 guidelines from 4 different continents (8 from Europe, 3 from South America, 1 from North America and 1 from Oceania). Our review demonstrated concordance between guidelines with regard to several aspects in the antibiotic treatment of UTI during pregnancy and in the follow-up after treatment. Nonetheless, there are some areas of discordance, as in the case of antenatal screening for bacteriuria and the use of fluoroquinolones in lower or upper UTI. Given the current evidence that we have from international guidelines, they all agree on several key points about antibiotic use.

17.
J Clin Med ; 11(17)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36079058

RESUMO

Ureteral access sheaths (UASs) are part of urologist's armamentarium when performing retrograde intrarenal surgery (RIRS). Recently, the world of RIRS has changed dramatically with the development of three game-changers: thulium fiber laser (TFL), smaller size single use digital flexible ureterosopes and intraoperative intrarenal pressure (IRP) measurement devices. We aimed to clarify the impact of UASs on IRP, complications and SFRs and put its indications in perspective of these three major technological improvements. A systematic review of the literature using the Medline, Scopus and Web of Science databases was performed by two authors and relevant studies were selected according to PRISMA guidelines. Recent studies showed that using a UAS lowers IRP and intrarenal temperature by increasing irrigation outflow during RIRS. Data on the impact of a UAS on SFRs, postoperative pain, risk of infectious complications, risk of ureteral strictures and risk of bladder recurrence of urothelial carcinoma after diagnostic RIRS were inconclusive. Prestenting for at least one week resulted in ureteral enlargement, while the influence of pre-operative administration of alpha-blockers was unclear. Since TFL, smaller single use digital ureteroscopes and devices with integrated pressure-measuring and aspiration technology seemed to increase SFRs and decrease pressure and temperature related complications, indications on the use of a UAS may decrease in the near future.

18.
Eur Urol Open Sci ; 44: 84-91, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36071820

RESUMO

Context: Nowadays, urolithiasis has become a highly prevalent disease. Recent studies indicate that retrograde intrarenal surgery (RIRS) is becoming more popular among surgical treatments due to the preference of patients and providers. This minimally invasive procedure results in high stone-free rates and relatively low morbidity; however, complications resulting from infection can still occur, including acute urinary tract infection, systemic inflammatory response syndrome, and sepsis. Objective: To identify the independent risk factors for sepsis following RIRS, as well as general risk factors that may contribute to this life-threatening complication in the pre- and intraoperative periods. Evidence acquisition: A literature review was conducted in April 2020 using the Medline, Scopus, and Cochrane databases. We searched the references of included papers. Evidence synthesis: We screened 2306 manuscripts and selected 13 for inclusion. The sepsis rate ranged from 0.5% to 11.1%, and the septic shock rate ranged from 0.3% to 4.6%. All selected studies mentioned risks for sepsis and/or infective complications (including sepsis), but only four of them addressed independent risks for urosepsis. These independent risk factors were stone size, high irrigation pressure, prolonged stent dwelling time (>30 d), sepsis as an indication for stent insertion, female gender, positive intraoperative bladder urine culture, longer surgical time, and diabetes mellitus. Conclusions: RIRS is associated with a low sepsis rate, according to the latest evidence. However, given that this is a serious life-threatening complication, knowing its potential risk factors is extremely important. Patient summary: In this report, we looked at the outcome of sepsis after planned retrograde intrarenal surgery for stone disease in patients with and without comorbidities. This information may be useful for colleagues in their daily practice.

19.
J Endourol ; 36(12): 1511-1521, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35972727

RESUMO

Introduction: Incidence of urolithiasis in children has increased in recent years and with technological advancements and miniaturization of surgical instruments, pediatric urologists have acquired an impressive arsenal for their treatment. Retrograde intrarenal surgery (RIRS) has gained widespread popularity as it is a natural extension of semirigid ureteroscopy and can be done through natural orifice minimizing the morbidity of percutaneous access. The aim of this narrative review is to describe how RIRS has evolved over the decades in children and if the age-related anatomical difference impacts reported outcomes especially stone-free rate (SFR) and complications. Materials and Methods: An electronic literature search from inception to October 15, 2021 was performed using Medical Subject Heading terms in several combinations on PubMed, EMBASE, and Web of Science without language restrictions. A total of 2022 articles were founded and 165 articles were full-text screening. Finally, 2 pediatric urologists included 51 articles that summarize the available literature regarding the development and use of RIRS in children. Results: RIRS as of today is well established as a superior modality for all stones in all locations compared with extracorporeal shockwave lithotripsy both in children and adults. The passive dilation has decreased the need of active ureteral dilation, but the need to perform prestenting is not defined yet. Regarding the use of the ureteral access sheath, the literature tends to lean toward its placement in most cases, but we do not know its long-term effects over the growth of children. Finally, the SFR has increased as the experience of pediatric urologists increases, as well as the number of complications has decreased. Conclusion: RIRS in pediatrics has crossed many milestones, yet many areas need further research and larger data are required to make RIRS the procedure of choice for renal stone management in children across all age groups.


Assuntos
Urolitíase , Criança , Humanos , Urolitíase/cirurgia
20.
World J Urol ; 40(9): 2313-2321, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35933626

RESUMO

INTRODUCTION: Since the construction of the first laser, many companies around the world have contributed to the development of new lasers technologies. To be user-friendly, some companies have developed a pre-setting mode in their laser devices. We aimed to review and compare all laser companies' pre-settings (PS) already established in the market. MATERIALS AND METHODS: An online search of holmium:YAG (Ho:YAG) and thulium fiber laser (TFL) devices was carried out. Manual and PS mode, pulse width and pulse modulation technology data were collected. The PS parameters were collected directly from the brochure devices or by asking the companies consulting agents. RESULTS: Thirty-nine laser devices were analyzed (33 Ho:YAG and 6 TFL). The power range varies from 15 to 152 W and 35 W to 60 W for Ho:YAG and TFL, respectively. PS are present in 66% of Ho:YAG lasers and the 33% of TFL. Long-pulse modes can be modified in 12 Ho:YAG and 1 TFL lasers. The median (IQR) PS for dusting stones with Ho:YAG laser is 0.4 J (0.2-1), 21.5 Hz (5-120), and 10 W (1.5-28) for energy, frequency and power, respectively; for Ho:YAG fragmentation is 0.8 J (0.3-5), 10 (3-15) Hz and 5 (1.5-50) W for energy, frequency, and power, respectively; and for popcorn is 0.8 J (0.4-1.2), 10 Hz (6-15) and 5 W (4-18) for energy, frequency, and power, respectively. Dusting and fragmentation mode of Rocamed MH01 and EMS LaserClast 35 are programmed according to the stone type. Most of these settings do not depend on the size of the fiber being used nor the location and type of stone. For TFL, the pre-sets are divided in bladder stone, dusting, fine dusting, fragmentation, and ureteral stone. CONCLUSION: There is a huge variability regarding pre-sets offered by companies because there is no consensus. Pre-sets should provide a range to work efficacy and safety.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos da Bexiga Urinária , Hólmio , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA